Description
Main Feature
- Using three different principle sensors to form an array sensor group, the response time is faster and the anti-interference performance is stronger;
- Self-created core algorithm, temperature and zero point compensation;
- Built-in high-precision constant-current sampling pump, large monitoring range and short response time;
- PELICAN protective box design, protection grade IP65, rainproof, dustproof, and salt spray proof;
- Use pattern recognition technology to quickly and accurately determine the odor index;
- Small size, easy to carry, can be carried by hand, and can be equipped with a single shoulder strap;
Application Areas
- Sewage treatment plant inspection
- Landfill plant inspection
- Chemical plant emissions testing
- Odor gas detection in rivers
- Industrial park emission testing
- Emission testing of food processing plants
- Detection of places with various unknown odors
Monitoring Parameters
| Detection principle | Electrochemistry, Photoionization (PID), Semiconductors |
| Sampling method | pump suction |
| Measuring range | Odor level: 0~70
Ammonia NH3: (0~100)ppm; Hydrogen sulfide H₂S: (0~100)ppm; Methyl mercaptan CH4S: (0~20)ppm; Volatile organic compounds V0CS: (0~50)ppm, (0~6000)ppm optional; |
| resolution | Odor level: 5
NH3:0.1ppm; H2S:0.1ppm; CH4S: 0.1ppm; VOCS: 5ppb, 100ppb optional; |
| error | ≤±5% |
| Working power supply | 110VAC~240V AC, built-in lithium battery can work continuously for 8 hours (can be expanded) |
| Power consumption | 15W |
| output signal | USB, RS232, GPRS, RS485, network port, DIDO, etc. |
| Response time | T90<15s(NH3<60s) |
| Display method | 800X480 LCD 7-inch touch screen |
| ambient temperature | -20℃~+50℃ |
| environment humidity | 0~95%RH (no condensation) |
| Environmental pressure | 65kPa~115kPa |
| Dimensions | 420X200X350mm length X width X height |
| weight | 7Kg |








Reviews